Product Description
Outback VFX3524M,24VDC,120VAC 3500W Inverter MOBILE
Outback Power Systems
|
FX2012MT
|
This inverter comes with the "Turbo" option in place. The external ventilation improves the operating efficiency of the inverter, yet maintains the air tight seal which protects internal components for dust and corrosion.
|
|
|
VFX2812M
|
- ULTRA CLEAN AC POWER
- Smooth, true sinewave AC output waveform -not an old fashioned modified Sinewave/Squarewave.
- EXTREMELY RUGGED
- Built to survive dust, bugs, even rain and salt air. Choice of sealed FX or bug-proof VFX versions. Installation of the inverter in an RV is now less of a problem.
- EXTREMELY EFFICIENT
- Get more power out of your batteries – run larger AC loads longer.
- INTELLIGENT BATTERY CHARGER
- Advanced charging algorithms provide fast recharging while increasing battery life. Powerful: up to 125 amps.
- VERY QUIET
- The sealed FX inverters are virtually silent. The bugproof VFX inverters only have a variable speed thermostatically controlled fan. No more transformer buzz to annoy you.
- EASY SYSTEM EXPANSION
- Systems can grow with your needs – Stack inverters in parallel for more power, or in series for 120/240.
- SERVICEABLE
- Both FX and VFX inverter/chargers can be upgraded or serviced – even in the field.
- DEFEATABLE NEUTRAL TO GND SWITCHING
- Ground switching can be defeated for non-mobile applications or for multiple Inverter installations.
- CAPABLE TECH SUPPORT HELP
- You can call or email and ask questions of the engineers that designed your products – Tech support doesn’t get any better than that.
- COOLNESS FACTOR
- These inverters have a built in “WOW” factor to impress the neighbors and in-laws.
SPECIFICATIONS | FX2012MT | FX2024M | VFX2812M | VFX3524M |
Continuous Power @ 25°C | 2000 VA (Turbo*) | 2000 VA | 2800 VA | 3500 VA |
Nominal DC Input Voltage | 12 VDC | 24 VDC | 12 VDC | 24 VDC |
Nominal AC Voltage & Frequency | 120 VAC 60 Hz | 120 VAC 60 Hz | 120 VAC 60 Hz | 120 VAC 60 Hz |
Continuous Output AC RMS | 17amps | 17 amps | 23.3 amps | 29.2amps |
Idle Power (with AC output / no load) | 19-21 Watts | 18 to 20 watts | 19-21 Watts | 18 to 20 watts |
Efficiency (typical at 25oC & 75% load) | >90% | 92% | >90% | >90% |
Total Harmonic Distortion (voltage) | 2% / 5% | 2% / 5% | 2% / 5% | 2% / 5% |
Output Voltage Regulation | +/- 2% typical | +/- 2% typical | +/- 2% typical | +/- 2% typical |
Surge Power Capability – AC output | ||||
Peak (1mSec) |
56 amps AC | 70 amps AC | 56amps | 70 amps |
RMS (100mSec) |
40 amps AC | 50 amps AC | 40 amps AC | 50 amps AC |
Overload Capability (from 25oC start) |
||||
5 second |
4000 VA | 4800 VA | 4000VA | 5000 VA |
30 minutes | 2500 VA | 3200 VA | 3200W | 4000W |
Automatic AC Transfer Relay | 30 amps AC | |||
AC Input Current | 30 amps AC | |||
AC Input Voltage Range | 80-150VAC | |||
Frequency Range – AC input | 50-70 Hz | |||
DC Input Voltage Range | 10 – 16 V | 20 – 33 V | 10-16V | 20-33V |
Recommended DC Breaker | OBDC-250 | OBDC-175 | OBDC-250 | OBDC-250 |
Continuous Battery Charger Output | 100 | 55 | 125 | 85 |
Battery Charging Regulation Method | 5 stage (bulk/absorb/float/silent/manual EQ) | |||
Operating Temperature Range | -40°C to 60°C (derate 20VA/°C over 25°C) | |||
Environmental Rating | Waterproof to IEC 529 IP 65 | |||
Inverter Dimensions | 16.25” L x 8.25” W x 11.5”H | |||
Shipping Box Dimensions | 21.6” L x 12.75” W x 15.5” H | |||
Shipping Weight | 65 lbs | 60 lbs.- | 62 lbs. | 62 lbs. |
General Circuitry Layout for Marine/RV Systems
Reviews